K Rend Thincoat Render System onto Brickwork

Summary: K Rend Silicone TC 15 onto Brickwork 
 
Substrate: Clay, Concrete or Calcium Silicate Brick

 

Primer: K Rend R10 Bonding Aid

Apply by brush or roller. Allow to dry prior to application of next render coat. 

Preparatory Base Coat: K Rend HP12 Base Coat

Apply in two even passes with K Rend Alkali Resistant Reinforcing Mesh embedded across the entire area. Rule to line and level and finish the surface with a light horizontal scratch. Allow to cure for a minimum of one day.

Total Thickness: 5 mm 
  
Base Coat: K Rend HP12 Base Coat

Apply in one 5 mm pass. Rule to line and level and finish the surface with a float finish. 
Allow to cure for a minimum of 14 days. 

Total Thickness: 5 mm

 

Primer: K Rend Primer TC

Apply by brush or roller. Allow to cure for a minimum of 24 hours prior to application of final finish coat. 
 
Finish Coat: K Rend Silicone TC 15

Apply by hand or machine to the thickness of largest aggregate. Allow to take up slightly prior to rubbing up to create the final texture. Surface should be rubbed uniformly to finish.

 

 

Disclaimer: The above is a high-level breakdown for a specified render system and was fully up to date and correct at the time of writing. Whilst we endeavour to ensure this page is kept up to date in line with any changes made by the manufacturer, we strongly recommend customers verify the above information directly with the manufacturer prior to a making a purchase or the application of any products and do not rely solely on the information provided above when making a decision. We accept no liability or responsibility for losses or damages occurring as a result of a customer’s failure to comply verify the above information. The render system should be applied in strict accordance with the manufacturer's instructions and specifications. These can be obtained directly from the manufacturer.

K Rend Thincoat Render System onto Brickwork